TY - JOUR
T1 - A Computational Multinephron Model for Small-Scale Preclinical Renal Dosimetry in Radiopharmaceutical Therapy
AU - Andersson, Michelle
AU - Goudin, Nicolas
AU - Pontoglio, Marco
AU - Reynaert, Nick
AU - Levillain, Hugo
AU - Saldarriaga Vargas, Clarita
N1 - Score=10
Publisher Copyright:
© 2026 by the Society of Nuclear Medicine and Molecular Imaging.
PY - 2026/10/30
Y1 - 2026/10/30
N2 - Nonuniform radiopharmaceutical uptake in kidney tissues leads to substructure-level absorbed dose heterogeneity, confounding the establishment of absorbed dose–effect relationships for nephrotoxicity in radiopharmaceutical therapy. We developed a model to enable nephron-level dosimetry. Methods: A multinephron computational model was developed on the basis of 3-dimensional multiphoton microscopy data, including different nephron types (superficial, midcortical, and juxtamedullary) and their main substructures (glomerulus, proximal tubule [PT], and distal tubule) in kidney tissues. Nephron-level S values were determined using Monte Carlo calculations for several β−- and α-emitting radionuclides. The multinephron dosimetry framework was applied to nonuniform kidney tissue uptake data on 225Ac, located primarily in midcortical and juxtamedullary PTs. Results: A nonuniform substructure activity distribution resulted in pronounced absorbed dose heterogeneities. S values varied substantially among nephron types, with the largest in juxtamedullary substructures. The self-dose to PTs was 7.6–15 times higher than the S value of superficial PTs for the α-emitters considered. The cross dose to juxtamedullary glomeruli was on average 20% higher than to superficial glomeruli. The case study revealed substantial absorbed dose heterogeneity, with the absorbed dose to the different PTs being 40%–73% higher than to their respective glomeruli. Additionally, the contribution of free 213Bi to the total absorbed dose differed from that of 225Ac. Conclusion: The developed multinephron framework enables nephron-level dosimetry, allowing quantification of absorbed dose heterogeneity within renal tissues. Such insights enable establishing critical nephron substructures for nephrotoxicity in radiopharmaceutical therapy, supporting nephroprotective strategies during clinical translation of novel radiopharmaceuticals.
AB - Nonuniform radiopharmaceutical uptake in kidney tissues leads to substructure-level absorbed dose heterogeneity, confounding the establishment of absorbed dose–effect relationships for nephrotoxicity in radiopharmaceutical therapy. We developed a model to enable nephron-level dosimetry. Methods: A multinephron computational model was developed on the basis of 3-dimensional multiphoton microscopy data, including different nephron types (superficial, midcortical, and juxtamedullary) and their main substructures (glomerulus, proximal tubule [PT], and distal tubule) in kidney tissues. Nephron-level S values were determined using Monte Carlo calculations for several β−- and α-emitting radionuclides. The multinephron dosimetry framework was applied to nonuniform kidney tissue uptake data on 225Ac, located primarily in midcortical and juxtamedullary PTs. Results: A nonuniform substructure activity distribution resulted in pronounced absorbed dose heterogeneities. S values varied substantially among nephron types, with the largest in juxtamedullary substructures. The self-dose to PTs was 7.6–15 times higher than the S value of superficial PTs for the α-emitters considered. The cross dose to juxtamedullary glomeruli was on average 20% higher than to superficial glomeruli. The case study revealed substantial absorbed dose heterogeneity, with the absorbed dose to the different PTs being 40%–73% higher than to their respective glomeruli. Additionally, the contribution of free 213Bi to the total absorbed dose differed from that of 225Ac. Conclusion: The developed multinephron framework enables nephron-level dosimetry, allowing quantification of absorbed dose heterogeneity within renal tissues. Such insights enable establishing critical nephron substructures for nephrotoxicity in radiopharmaceutical therapy, supporting nephroprotective strategies during clinical translation of novel radiopharmaceuticals.
KW - Multinephron mouse kidney model
KW - Small-scale dosimetry
KW - MIRD
KW - Radiopharmaceutical therapy
UR - https://ecm.sckcen.be/OTCS/llisapi.dll/open/96728198
UR - https://www.scopus.com/pages/publications/105026608015
U2 - 10.2967/jnumed.125.270151
DO - 10.2967/jnumed.125.270151
M3 - Article
SN - 0161-5505
VL - 67
SP - 126
EP - 131
JO - Journal of Nuclear Medicine
JF - Journal of Nuclear Medicine
IS - 1
M1 - 125.270151
ER -