Comparison between point defect generation by γ-rays in bulk and fibre samples of high purity amorphous SiO2

Benoit Brichard, Simonpietro Agnello, Laura Nuccio

    Research outputpeer-review

    Abstract

    We compare the E', H(I) and Si-ODqII) contents in a low-OH high-purity a-Si02 either in bulk or fibre form s. We found that the H(I) centre appears during irradiation and tend to increase with the dose if the fibre contains hydrogen excess. This behaviour is believed to be one the possible reason to explain the apparent radiation-sensitivity enhancement in the blue-UV spectrum when the fibre is hydrogenated and irradiated at high dose. However for the hydrogen-treated fibres, no experimental repeatability could be evidenced in the measurements of E' and Si-ODC(II) although an acceptable agreement was still found in normal samples. Thi s suggests a possible complex reactional mechanisms in pre sence of gamma radiation when the glass has a hydrogen excess.

    Original languageEnglish
    Title of host publication2007 9th European Conference on Radiation and Its Effects on Components and Systems, RADECS 2007
    DOIs
    StatePublished - 2007
    EventRADECS - 2007: 9th European Conference on Radiation and Its Effects on Components and Systems - Deauville
    Duration: 10 Sep 200714 Sep 2007

    Publication series

    NameProceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS

    Conference

    ConferenceRADECS - 2007
    Country/TerritoryFrance
    CityDeauville
    Period2007-09-102007-09-14

    ASJC Scopus subject areas

    • Radiation
    • Electrical and Electronic Engineering

    Cite this