Corrosion behavior and mechanical properties of V-4Cr-4Ti alloy exposed at 500 and 700 ◦C to static Pb with ~10-9 mass% dissolved oxygen for 1000 h

Valentyn Tsisar, Takuya Nagasaka, Olga Yeliseyeva, Jun Lim, Jürgen Konys, Takeo Muroga, Carsten Schroer

    Research outputpeer-review

    Abstract

    The corrosion tests of V-4Ti-4Cr alloy (NIFS HEAT 2) tensile samples were carried out in static liquid Pb with ~10-9 mass% dissolved oxygen at 500 and 700 ◦C for 1000 h. A clear intergranular corrosion attack was observed on the surface of the samples. Corrosion losses increase ten times, from around 3.0 μm to 30 μm, as the temperature increased from 500 ◦C to 700 ◦C, respectively. The alloy remained ductile after the tests at both temperatures. A phenomenology of interaction processes in Pb[O]-V[Cr,Ti] system is discussed.
    Original languageEnglish
    Article number155052
    Number of pages8
    JournalJournal of Nuclear Materials
    Volume595
    DOIs
    StatePublished - Jul 2024

    ASJC Scopus subject areas

    • Nuclear and High Energy Physics
    • General Materials Science
    • Nuclear Energy and Engineering

    Cite this