TY - JOUR
T1 - Determination of the uranium enrichment without calibration standards using a 2 × 2 inch LaBr3 (Ce) room temperature detector and Monte Carlo sampling approach for uncertainty assessment
AU - Meleshenkovskii, Iaroslav
AU - Pauly, Nicolas
AU - Labeau, Pierre-Etienne
N1 - Score=10
PY - 2018/12/31
Y1 - 2018/12/31
N2 - In recent years room temperature medium resolution scintillation devices, such as LaBr3(Ce), have attracted much interest as possible alternatives to traditional spectrometers based on HPGe and NaI detectors, for the determination of the uranium enrichment in safeguards applications. This paper focuses on the investigation of possibilities and limits of a net peak area based methodology used for the determination of the uranium enrichment without use of calibration standards and introduces the isotopic code MCSIGMA for LaBr3(Ce) scintillators. Tests are conducted with a room temperature, medium resolution spectrometer based on a 2×2 inch LaBr3(Ce) scintillator using which spectra of different statistical quality are obtained from certified uranium standards. Gamma peaks in the 143-1001keV energy range are used as uranium gamma-ray signatures. Results indicate a promising performance of the applied methodology with a room temperature medium resolution scintillator of the LaBr3(Ce) type, however at a cost of significantly higher uncertainty budget on the derived enrichment compared to HPGe, especially for natural and depleted uranium samples. This uncertainty budget is primarily influenced by the statistical quality of the measured spectra. Implemented algorithms and analysis routines are described in detail and presented.
AB - In recent years room temperature medium resolution scintillation devices, such as LaBr3(Ce), have attracted much interest as possible alternatives to traditional spectrometers based on HPGe and NaI detectors, for the determination of the uranium enrichment in safeguards applications. This paper focuses on the investigation of possibilities and limits of a net peak area based methodology used for the determination of the uranium enrichment without use of calibration standards and introduces the isotopic code MCSIGMA for LaBr3(Ce) scintillators. Tests are conducted with a room temperature, medium resolution spectrometer based on a 2×2 inch LaBr3(Ce) scintillator using which spectra of different statistical quality are obtained from certified uranium standards. Gamma peaks in the 143-1001keV energy range are used as uranium gamma-ray signatures. Results indicate a promising performance of the applied methodology with a room temperature medium resolution scintillator of the LaBr3(Ce) type, however at a cost of significantly higher uncertainty budget on the derived enrichment compared to HPGe, especially for natural and depleted uranium samples. This uncertainty budget is primarily influenced by the statistical quality of the measured spectra. Implemented algorithms and analysis routines are described in detail and presented.
KW - Uranium enrichment
KW - Monte Carlo
UR - https://ecm.sckcen.be/OTCS/llisapi.dll/overview/48443998
U2 - 10.1140/epjp/i2018-12363-8
DO - 10.1140/epjp/i2018-12363-8
M3 - Article
SN - 2190-5444
VL - 133
SP - 1
EP - 19
JO - The European Physical Journal Plus
JF - The European Physical Journal Plus
IS - 554
ER -