TY - JOUR
T1 - EURADOS intercomparison on the usage of the ICRP/ICRU adult reference computational phantoms
AU - Zankl, Maria
AU - Eakins, Jon
AU - Goméz-Ros, José Maria
AU - Huet, Cristelle
AU - Jansen, Jan T.M.
AU - Moraleda, Montse
AU - Reichelt, Uwe
AU - Struelens, Lara
AU - Vrba, Tomáš
N1 - Score=10
PY - 2021/5/21
Y1 - 2021/5/21
N2 - The European Radiation Dosimetry Group, EURADOS, has organised an intercomparison study on the usage of the ICRP/ICRU voxel reference computational phantoms together with radiation transport codes. Voluntary participants have been invited to solve specific tasks and provide solutions to the organisers before a certain deadline. The tasks to be solved are of practical interest in occupational, environmental and medical dosimetry.
The aims of this training activity were to investigate if the phantoms have been correctly implemented in the radiation transport codes and to give the participants the opportunity to check their own calculations against
quality-assured master solutions and improve their approach, if needed.
AB - The European Radiation Dosimetry Group, EURADOS, has organised an intercomparison study on the usage of the ICRP/ICRU voxel reference computational phantoms together with radiation transport codes. Voluntary participants have been invited to solve specific tasks and provide solutions to the organisers before a certain deadline. The tasks to be solved are of practical interest in occupational, environmental and medical dosimetry.
The aims of this training activity were to investigate if the phantoms have been correctly implemented in the radiation transport codes and to give the participants the opportunity to check their own calculations against
quality-assured master solutions and improve their approach, if needed.
KW - Intercomparison
KW - Reference computational phantoms
KW - Radiation transport codes
KW - Training
UR - https://ecm.sckcen.be/OTCS/llisapi.dll/open/47816605
U2 - 10.1016/j.radmeas.2021.106596
DO - 10.1016/j.radmeas.2021.106596
M3 - Article
SN - 1350-4487
VL - 145
SP - 1
EP - 5
JO - Radiation Measurements
JF - Radiation Measurements
M1 - 106596
ER -