TY - JOUR
T1 - Experimental determination of Q0 factors and effective resonance energies with a multi-channel approach: the α-vector method
AU - Farina Arboccò, F.
AU - Vermaercke, Peter
AU - Smits, Katrien
AU - Sneyers, Liesel
AU - Strackx, Maarten
AU - Strijckmans, K.
N1 - Score = 10
PY - 2014/7/24
Y1 - 2014/7/24
N2 - Some of the Q0 and E¯ r factors from the 2003 to
2012 recommended k0-datasets were adopted from older literature
(Lit; before 1984), at the time of the launch of the k0-
method and have associated uncertainties of 10 %. The E¯ r
factors on the other hand, were derived analytically in 1979 and
1987 byemploying the Breit–Wigner resonance representation,
but in 1984 a multi-channel method was proposed for simultaneous
Q0 andE¯ r experimental determination. In this work we
assumed the a-dependence of theE¯ r parameter proposed later in
1987 for a generalization of this method, which was then
employed in the experimental determination of Q0 andE¯ r factors
for 17 (n,c) target isotopes on up to three channels of the
BR1 reactor at the SCK-CEN(Mol, Belgium).Retrospectively,
this ‘‘a-vectormethod’’ can be employed for a-calibration and it
provides a practical way of averaging the experimentalQ0 (and
E¯
r) results from several laboratories.OurQ0 results have 2–3 %
uncertainty and are compared with the Lit elsewhere.
AB - Some of the Q0 and E¯ r factors from the 2003 to
2012 recommended k0-datasets were adopted from older literature
(Lit; before 1984), at the time of the launch of the k0-
method and have associated uncertainties of 10 %. The E¯ r
factors on the other hand, were derived analytically in 1979 and
1987 byemploying the Breit–Wigner resonance representation,
but in 1984 a multi-channel method was proposed for simultaneous
Q0 andE¯ r experimental determination. In this work we
assumed the a-dependence of theE¯ r parameter proposed later in
1987 for a generalization of this method, which was then
employed in the experimental determination of Q0 andE¯ r factors
for 17 (n,c) target isotopes on up to three channels of the
BR1 reactor at the SCK-CEN(Mol, Belgium).Retrospectively,
this ‘‘a-vectormethod’’ can be employed for a-calibration and it
provides a practical way of averaging the experimentalQ0 (and
E¯
r) results from several laboratories.OurQ0 results have 2–3 %
uncertainty and are compared with the Lit elsewhere.
KW - Neutron Activation
KW - Analysis
KW - Q0 factor
KW - Effective resonance energy E¯ r
KW - s0 factor
KW - Modified Westcott formalism
KW - k0 method
UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/ezp_136813
UR - http://knowledgecentre.sckcen.be/so2/bibref/11793
U2 - 10.1007/s10967-014-3276-x
DO - 10.1007/s10967-014-3276-x
M3 - Article
SN - 0236-5731
VL - 302
SP - 631
EP - 646
JO - Journal of Radioanalytical and Nuclear Chemistry
JF - Journal of Radioanalytical and Nuclear Chemistry
IS - 1
ER -