Fibre optic extensometer for high radiation and high temperature nuclear applications

G. Cheymol, J. F. Villard, A. Gusarov, B. Brichard

    Research outputpeer-review

    Abstract

    In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400°C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10-2 i.e 5000με for an increase in temperature of 300-400°C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100μm (< 1 μm error), at room temperature. The displacement measured can reach 250μm (20000με with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered.

    Original languageEnglish
    Title of host publicationANIMMA 2011 - Proceedings
    Subtitle of host publication2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications
    DOIs
    StatePublished - 2011
    Event2011 - ANIMMA - Advancements in Nuclear Instrumentation Measurement Methods and their Applications: International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications - Ghent
    Duration: 6 Jun 20119 Jun 2011

    Publication series

    NameANIMMA 2011 - Proceedings: 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications

    Conference

    Conference2011 - ANIMMA - Advancements in Nuclear Instrumentation Measurement Methods and their Applications
    Country/TerritoryBelgium
    CityGhent
    Period2011-06-062011-06-09

    ASJC Scopus subject areas

    • Nuclear Energy and Engineering

    Cite this