TY - JOUR
T1 - High-precision beam profile measurement with a microchannel-plate detector in the high magnetic field of the WISArD experiment
AU - Lecanuet, S.
AU - Fléchard, X.
AU - Alfaurt, P.
AU - Ascher, P.
AU - Atanasov, D.
AU - Blank, B.
AU - Daudin, L.
AU - DePreaumont, H.
AU - Gerbaux, M.
AU - Giovinazzo, J.
AU - Grévy, S.
AU - Guignard, G.
AU - Ha, J.
AU - Knapen, C.
AU - Lechner, S.
AU - Lépine, A.
AU - Lory, J.
AU - Perronnel, J.
AU - Pomorski, M.
AU - Roche, M.
AU - Roumegou, C.
AU - Severijns, N.
AU - Son, Y.
AU - Vanlangendonck, S.
AU - Versteegen, M.
AU - Zakoucky, D.
N1 - Publisher Copyright:
© 2026 The Authors
PY - 2026/9
Y1 - 2026/9
N2 - We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with 32Ar Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is configured in a Z-stack and has a resistive position sensitive anode, was tested with both stable and radioactive beams. This work focuses on the image reconstruction method, which corrects the pincushion distortion inherent to the square-shaped resistive anode, and investigates the influence of the magnetic field on the detector performance. Our results demonstrate that the detector achieves beam profile measurements with sub-millimeter accuracy, while coping with the spatial and high-magnetic field (4 T) constraints of the experiment. These capabilities meet the precision requirements of the WISArD experiment for extracting the modified beta-neutrino angular correlation coefficient, ãβν, with an uncertainty of 1‰.
AB - We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with 32Ar Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is configured in a Z-stack and has a resistive position sensitive anode, was tested with both stable and radioactive beams. This work focuses on the image reconstruction method, which corrects the pincushion distortion inherent to the square-shaped resistive anode, and investigates the influence of the magnetic field on the detector performance. Our results demonstrate that the detector achieves beam profile measurements with sub-millimeter accuracy, while coping with the spatial and high-magnetic field (4 T) constraints of the experiment. These capabilities meet the precision requirements of the WISArD experiment for extracting the modified beta-neutrino angular correlation coefficient, ãβν, with an uncertainty of 1‰.
KW - Magnetic field
KW - MCP
KW - Radioactive ion beam
KW - WISArD
UR - https://www.scopus.com/pages/publications/105035806245
U2 - 10.1016/j.nima.2026.171582
DO - 10.1016/j.nima.2026.171582
M3 - Article
AN - SCOPUS:105035806245
SN - 0168-9002
VL - 1089
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
M1 - 171582