TY - JOUR
T1 - k0-NAA, a valuable tool for reference-material producers
AU - Robouch, Piotr B.
AU - Eguskiza, M.
AU - Maguregui, M. I.
AU - Pommé, S.
AU - Pauwels, J.
PY - 2001
Y1 - 2001
N2 - The main concern of producers of certified reference materials (CRM) is the preparation of high-quality products with demonstrated homogeneity and stability, combined with a well established set of certified characteristics. CRM producers must, furthermore, comply with other constraints imposed by the ISO Guide 34: • production processes, production control, and certification analyses should be performed by expert laboratories, using validated protocols documented in their respective quality assurance manuals; • laboratory mean values and the corresponding "expanded" uncertainties, must be used for the determination of the certified values, as recommended by the ISO Guide to the Expression of Uncertainties in Measurements (GUM); and • when possible, traceability of the certified value to the SI units, using appropriately validated and/or primary methods, must be ensured. k0-NAA, i.e. neutron activation analysis with k0 standardization, is one of the analytical techniques implemented at the Reference Material Unit of IRMM; it meets the first two requirements.
AB - The main concern of producers of certified reference materials (CRM) is the preparation of high-quality products with demonstrated homogeneity and stability, combined with a well established set of certified characteristics. CRM producers must, furthermore, comply with other constraints imposed by the ISO Guide 34: • production processes, production control, and certification analyses should be performed by expert laboratories, using validated protocols documented in their respective quality assurance manuals; • laboratory mean values and the corresponding "expanded" uncertainties, must be used for the determination of the certified values, as recommended by the ISO Guide to the Expression of Uncertainties in Measurements (GUM); and • when possible, traceability of the certified value to the SI units, using appropriately validated and/or primary methods, must be ensured. k0-NAA, i.e. neutron activation analysis with k0 standardization, is one of the analytical techniques implemented at the Reference Material Unit of IRMM; it meets the first two requirements.
UR - http://www.scopus.com/inward/record.url?scp=0034947238&partnerID=8YFLogxK
U2 - 10.1007/s002160100820
DO - 10.1007/s002160100820
M3 - Article
AN - SCOPUS:0034947238
SN - 0937-0633
VL - 370
SP - 255
EP - 258
JO - Fresenius' Journal of Analytical Chemistry
JF - Fresenius' Journal of Analytical Chemistry
IS - 2-3
ER -