Abstract
The Institute for Reference Materials and Measurements operates a 7.0 MV Van de Graaff accelerator to generate monoenergetic neutron radiation for experimental applications. Owing to increased intensities of generated neutron fields and the more stringent regulation related to the maximum dose for the public, a concrete shielding wall surrounding the experimental building was constructed. This paper presents a study aiming at evaluating the effect of the shielding on the neutron field outside the wall. For this purpose, the following measurements were carried out around the building: (1) cartography of the neutron field for different experimental conditions; (2) measurement of neutron spectra using multiple Bonner spheres; (3) activation measurements using gold discs followed by low-level gamma spectrometry. From the measurements, it can be concluded that the wall fulfils its purpose to reduce the neutron dose rate to the surrounding area to an acceptable level.
Original language | English |
---|---|
Pages (from-to) | 711-715 |
Number of pages | 5 |
Journal | Radioation Protection Dosimitry |
Volume | 110 |
Issue number | 1-4 |
DOIs | |
State | Published - 2004 |
ASJC Scopus subject areas
- Radiological and Ultrasound Technology
- Radiation
- Radiology Nuclear Medicine and imaging
- Public Health, Environmental and Occupational Health