Abstract
This paper presents the assessment of the neutron field near the VENUS reactor, particularly in areas near the reactor shielding where operators are frequently present during a reactor run. To obtain reference spectra in the area of interest, MCNPX simulations were performed. Reference spectrometry was also performed using a Bonner spheres system. The outcome of both calculations and measurements is compared.
Original language | English |
---|---|
Pages (from-to) | 170-174 |
Number of pages | 5 |
Journal | Radiation protection dosimetry |
Volume | 125 |
Issue number | 1-4 |
DOIs | |
State | Published - 14 Jun 2007 |
Funding
This research was partly funded by the European Commission under the auspices of the Euratom 5th Framework Program: Nuclear Energy, 1998–2002, Contract No FIKR-CT-2001-00175. The authors wish to express their gratitude to the technical and scientific staff at SCK•CEN who helped during the campaign. Acknowledgements are also addressed to Dr. M. Reginatto (PTB) for useful discussions.
Funders | Funder number |
---|---|
Euratom 5th Framework Program | FIKR-CT-2001-00175 |