TY - JOUR
T1 - Performance assessment of a 500 mm3 CZT and a 2x2 inch LaBr3(Ce) detectors for the determination of the uranium enrichment using the enrichment-meter method and calibration standards for safeguards applications
AU - Meleshenkovskii, Iaroslav
AU - Pauly, Nicolas
AU - Labeau, Pierre-Etienne
N1 - Score=10
PY - 2020/2
Y1 - 2020/2
N2 - Determination of the uranium enrichment is an important safeguards verification task, routinely carried out using non-destructive assay methods. The enrichment-meter method is one of the most widely used passive non-destructive X- and gamma-ray based methods used for such tasks. Among its advantages is the highly constrained physical nature of its underlying formalism, allowing it to be used with high-resolution HPGe detectors, as well as with low-resolution NaI detectors. Due to attractive features and spectroscopic performance, CdZnTe and LaBr3(Ce) detectors raised interest in their application to such tasks as well. However, their spectroscopic performance is different to that of the traditional detectors in many ways. Application of the enrichment-meter method requires determination of the net peak areas corresponding to 235U signature photopeaks. The latter requires an adequate algorithm to select the region-of-interest boundaries, which may be sensitive to asymmetrical photopeaks of CZT detectors. In this paper we conduct a performance assessment of a 500 mm3 CZT detector of a quasi-hemispherical design and a 2 × 2 inch LaBr3(Ce) scintillator with the enrichment-meter method using a set of certified uranium standards with enrichment degrees from 0.31% to 4.46% of 235U atomic abundance. We investigate the impact of different methods used for net peak area determination, statistical quality of acquired spectra and size of region-of-interest boundaries on accuracy and uncertainty. We propose an algorithm for symmetrical/asymmetrical region-of-interest boundaries determination and make recommendations on the best combinations of the region-of-interest size and method used for the net peak area determination for each of the detectors. The underlying routines of the algorithm and analysis procedures are described in detail and results are presented.
AB - Determination of the uranium enrichment is an important safeguards verification task, routinely carried out using non-destructive assay methods. The enrichment-meter method is one of the most widely used passive non-destructive X- and gamma-ray based methods used for such tasks. Among its advantages is the highly constrained physical nature of its underlying formalism, allowing it to be used with high-resolution HPGe detectors, as well as with low-resolution NaI detectors. Due to attractive features and spectroscopic performance, CdZnTe and LaBr3(Ce) detectors raised interest in their application to such tasks as well. However, their spectroscopic performance is different to that of the traditional detectors in many ways. Application of the enrichment-meter method requires determination of the net peak areas corresponding to 235U signature photopeaks. The latter requires an adequate algorithm to select the region-of-interest boundaries, which may be sensitive to asymmetrical photopeaks of CZT detectors. In this paper we conduct a performance assessment of a 500 mm3 CZT detector of a quasi-hemispherical design and a 2 × 2 inch LaBr3(Ce) scintillator with the enrichment-meter method using a set of certified uranium standards with enrichment degrees from 0.31% to 4.46% of 235U atomic abundance. We investigate the impact of different methods used for net peak area determination, statistical quality of acquired spectra and size of region-of-interest boundaries on accuracy and uncertainty. We propose an algorithm for symmetrical/asymmetrical region-of-interest boundaries determination and make recommendations on the best combinations of the region-of-interest size and method used for the net peak area determination for each of the detectors. The underlying routines of the algorithm and analysis procedures are described in detail and results are presented.
KW - CdZnTe
KW - LaBr3(Ce)
KW - Room temperature
KW - Uranium enrichment
KW - Enrichment-meter
KW - safeguards
UR - http://ecm.sckcen.be/OTCS/llisapi.dll/open/35931261
U2 - 10.1016/j.apradiso.2019.108975
DO - 10.1016/j.apradiso.2019.108975
M3 - Article
SN - 0969-8043
VL - 156
SP - 1
EP - 12
JO - Applied Radiation and Isotopes
JF - Applied Radiation and Isotopes