title = "Post-irradiation creep properties of cold-worked 316 stainless steel as measured with small creep specimens.",
abstract = "Small specimens (4 mm gage length, 1. 3 mm diameter) of AISI 20% cold-worked (CW) 316 stainless steel have been irradiated at 700 degree C up to 2 multiplied by 10**2**2 n/cm**2. Ageing at 650 degree C as well as irradiation caused a reduction in creep life and an increase in minimum creep rate as compared with as-received specimens. An investigation of a possible size effect indicated no difference between creep results obtained on these small specimens and on larger ones.",
author = "W. Vandermeulen and M. Snykers and {Van Asbroeck}, Ph",
year = "1986",
language = "English",
isbn = "0803104405",
series = "ASTM Special Technical Publication",
publisher = "ASTM International",
pages = "252--257",
editor = "W.R. Corwin and G.E. Lucas",
booktitle = "ASTM Special Technical Publication",
}