T1 - Real-time fibered optically stimulated luminescence dosimeter based on SrS:Ce,Sm phosphor
AU - Benoit, D.
AU - Garcia, Pierre
AU - Matias-Vaillé́, S.
AU - Ravotti, F.
AU - Vaillé́, J. R.
AU - Glaser, M.
AU - Brichard, B.
AU - Fernandez, A. F.
AU - Chatry, C.
AU - Dusseau, L.
PY - 2007
Y1 - 2007
N2 - A novel real-time optical fibered dosimetry system based on optically stirn ulated luminescence (OSL) of SrS:Ce,Sm phosphor was developed and is presented. The advantages of this system are the combination of OSL and optical fibers, immediate readout, simplicity of use, low cost, reliability, flexibility, and robustness. Experimental results show an excellent linearity with the dose (0.01 to 6 Gy), repeatability better than 2%, radiation sensitivity up to 80 mV.cGy-1 and accuracy since error on dose is less than 5%. The applications targeted are the measurement of the dose delivered during a treatment in radiation therapy and the monitoring of the dose or dose-rate around or in nuclear reactor and accelerator facilities in high energy physics. Further experiments are still to be conducted in order to fully characterize the system and evaluate the feasibility of each application mentioned.
AB - A novel real-time optical fibered dosimetry system based on optically stirn ulated luminescence (OSL) of SrS:Ce,Sm phosphor was developed and is presented. The advantages of this system are the combination of OSL and optical fibers, immediate readout, simplicity of use, low cost, reliability, flexibility, and robustness. Experimental results show an excellent linearity with the dose (0.01 to 6 Gy), repeatability better than 2%, radiation sensitivity up to 80 mV.cGy-1 and accuracy since error on dose is less than 5%. The applications targeted are the measurement of the dose delivered during a treatment in radiation therapy and the monitoring of the dose or dose-rate around or in nuclear reactor and accelerator facilities in high energy physics. Further experiments are still to be conducted in order to fully characterize the system and evaluate the feasibility of each application mentioned.
KW - Dosimetry
KW - Optically Stimulated Luminescence (OSL)
KW - Optical fibers
UR - http://www.scopus.com/inward/record.url?scp=70449589820&partnerID=8YFLogxK
U2 - 10.1109/RADECS.2007.5205486
DO - 10.1109/RADECS.2007.5205486
M3 - In-proceedings paper
AN - SCOPUS:70449589820
SN - 9781424417049
T3 - Proceedings of the European Conference on Radiation and its Effects on Components and Systems, RADECS
BT - 2007 9th European Conference on Radiation and Its Effects on Components and Systems, RADECS 2007
T2 - RADECS - 2007
Y2 - 10 September 2007 through 14 September 2007
ER -