Temperature dependence of liquid metal embrittlement susceptibility of a modified 9Cr-1Mo steel under low cycle fatigue in lead-bismuth eutectic at 160-450°C

Xing Gong, Pierre Marmy, Ling Qin, Bert Verlinden

    Research outputpeer-review

    Abstract

    LCF fatigue properties have been tested in a low oxygen concentrration LBE and in vacuum at 160-450°C. LME is not very sensitive to temperature during the fatigue crack propagation.
    Original languageEnglish
    Pages (from-to)289-298
    Number of pages10
    JournalJournal of Nuclear Materials
    Volume468
    DOIs
    StatePublished - 14 Jun 2015

    Cite this