Two-dimensional bkutron and gamma calculations for devices irradiated in br2 reflector positions

Charles M. De Raedt, Serge F. Bodart, Bernard J. Ponsard, Marcel J. Wéber, Thierry Maldague

    Research outputpeer-review

    Abstract

    For two typical LWR fuel rod irradiation devices introduced into the BR2 reflector two-dimensional neutron and gamma calculations are being carried out. In the first case a single fuel rod surrounded by several pressure tubes and by a time-variable neutron screen (He-3 gas at various pressures) is studied. The calculations are carried out in R,0 geometry, centered on the irradiated fuel rod. In the second case a bundle of nine fuel rods in a 3x3 square lattice is irradiated. Here the calculations are performed in X,Y geometry. The necessity is discussed of performing two-dimensional calculations for these irradiations in the BR2 reflector, to improve the modelling of the fuel behaviour.

    Original languageEnglish
    Title of host publicationReactor Dosimetry
    EditorsHarry Farrar, E. Parvin Lippincott, John G. Williams, David W. Vehar
    PublisherASTM International
    Pages608-617
    Number of pages10
    ISBN (Electronic)9780803118997
    DOIs
    StatePublished - 1994
    Event1993 - 8th ASTM-EURATOM symposium on reactor dosimetry - Vail
    Duration: 29 Aug 19933 Sep 1993

    Publication series

    NameASTM Special Technical Publication
    VolumeSTP 1228
    ISSN (Print)0066-0558

    Conference

    Conference1993 - 8th ASTM-EURATOM symposium on reactor dosimetry
    Country/TerritoryUnited States
    CityVail
    Period1993-08-291993-09-03