WEBEXPIR: Windowless target electron beam experimental irradiation

Marc Dierckx, Paul Schuurmans, Jan Heyse, Kris Rosseel, Katrien Van Tichelen, Benoit Nactergal, Dirk Vandeplassche, Thierry Aoust, Michel Abs, Arnaud Guertin, Jean-Michel Buhour, Arnaud Cadiou, Hamid Aït Abderrahim

    Research outputpeer-review

    Abstract

    The aim of the WEBEXPIR experiment was to check for any LBE surface distortion or enhanced evaporation as a result of surface heating with a 7 MeV electron beam in conditions representative of the MYRRHA/XT-ADS spallation target. Various tests have been carried out at electron beam currents of up to 10 mA, which corresponds to 40 times the nominal beam current necessary to reproduce surface heating in relevant conditions. No significant shockwave effects or enhanced LBE evaporation were detected. As a first preliminary conclusion it can be stated that the WEBEXPIR free surface flow was not disturbed by the interaction with the electron beam and that the vacuum conditions stay well within design specifications of the MYRRHA/XT-ADS application.
    Original languageEnglish
    Pages (from-to)302-306
    JournalJournal of Nuclear Materials
    Volume376
    Issue number3
    DOIs
    StatePublished - 15 Jun 2008